Flip station calibration: This routine determines 
the number of motor steps it takes for the carrier to 
descend from the “rest position datum” (Edge 
A
 in the 
diagram) to the “real” rest position, that being the 
carrier’s physical end stop.This stored number is used 
to drive the carrier down to the rest position before 
each and every flip station action. 
Calibraton is a one-time setup routine, but is also 
a useful starting point when diagnosing flip 
station problems. 
Power OFF. Lift the cover, then push the carrier 
down to its physical end stop. Push at the back of 
the carrier, near the guide shaft. Do 
NOT
 force! 
Click Flip Station Calibration. This elevates the 
carrier until Edge 
A
 just clears the photo sensor, at 
which point the motor stops, and the step count is 
saved in flash memory. The motor then drives the 
carrier back down to the rest position. 
Carrier Motion
Vertical motion of the carrier is detected by a single 
photo sensor, activated by two tabs at the back of the 
carrier molding. The carrier is positioned by counting 
a specific number of motor steps from the instant 
the sensor’s optical path is opened or closed by 
edges A, B and C.
Flip station components 
The two halves of the sensor (arrow) are 
contained in cavities in the molded back wall of the 
flip station. The sensor tabs are integral with the 
carrier molding. Edge C is hidden by the card ejector 
arm. 
Flip Station Parameters in the Driver
Start
 > Printers (or Printers and Faxes) > Right 
click Zebra P640i > Properties > Device Settings 
> Printer Adjustment > 
Flip Station Adjust
 
Card Position Adjust (Pixels): Adjusts how far 
the truck drives into the flip station. Should be set so 
that the card is centered in the flip arms (if it isn’t 
centered, the truck may have difficulty removing the 
card after the flipping action). If the card position is 
incorrect, the truck can depart, leaving the card in the 
flip arms, 
or it may 
drag the 
card an 
inch or two 
toward the 
print 
station, 
then jam. 
 Start
 > 
Printers (or 
Printers and Faxes) > Right click Zebra P640i > 
Properties > Device Settings > Control > Advanced 
Utilites > 
Move Truck
 (to Flip Station) 
In 
1
, the card should drive smoothly to rest 
almost 
touching
 the right hand edge of the flip station base 
molding. It must not rebound off the edge. To move 
the card further to the right, increase (make less 
negative) the Card Adjust parameter, and vice versa. 
Now click 
Flip Test 3 
with Flip 
enabled. 
The card 
should 
land as 
2
, with a gap of between 0.04" and 0.1" (1 to 
2.5 mm). The exact gap isn’t critical, but it has to be 
visibly there. 
Rest 
Position 
Adjust: 
Adjusts 
how far 
down the 
carrier 
drives. 
This 
parameter 
is the 
number of 
motor 
steps, 
more or 
less, 
relative to 
the Edge 
A
 
event at 
the photo 
sensor 
(diagram 
Platen
Card
Truck