Справочник Пользователя для Zebra Technologies S4M

Скачать
Страница из 132
103
Troubleshooting
Printer Diagnostics
10/21/05
S4M User Guide
13290L-001 Rev. A
FEED and PAUSE Self Test
Performing this self test temporarily resets the printer configuration to the factory default 
values. These values are active only until power is turned off unless you save them 
permanently in memory. If the factory default values are permanently saved, a media 
calibration procedure must be performed.
To perform a FEED and PAUSE self test, complete these steps:
1.
Turn Off (O) the printer.
2.
Press and hold 
FEED
 and 
PAUSE
 
while turning the power On (I). 
3.
Hold 
FEED
 and 
PAUSE
 until the first control panel light turns off.
The printer configuration is temporarily reset to the factory default values. No labels print 
at the end of this test.
Communications Diagnostics Test
Do not perform the following test until all configuration and calibration parameters have been 
set. For configuration information, see 
This test is controlled from the control panel LCD display. See 
 shows a typical printout from this test. Turn the printer power Off (O) and then back 
On (I) to exit this self test and return to normal operation.
Figure 33 • Communications Diagnostics Test Label
Note • 
This test label prints upside-down.