Справочник Пользователя для Zebra Technologies S4M

Скачать
Страница из 132
Configuration
Password Protection of Parameters
54
13290L-001 Rev. A
S4M User Guide
10/21/05
Password Protection of Parameters
The printer has four levels of passwords. When you enter Setup mode on the control panel, 
only those parameters that are not password-protected are displayed. To see more parameters, 
you must enter an appropriate password at the 
ADVANCED SETUP
 prompt. After you enter a 
password correctly, you do not have to enter it again until you leave and reenter Setup mode.
When you are prompted for a password, enter the password for the level displayed or for a 
higher level. Entering a higher level password will unprotect the parameters for that level and 
for all levels below it (for example, unprotecting level 4 parameters also unprotects levels 1, 2, 
and 3).
The password levels and default passwords are shown in 
. To change the password for 
any level, use the 
^KP
 ZPL II command. For more information, see 
To enter a password when prompted, complete these steps:
1.
When the printer displays 
ADVANCED SETUP X
, press ENTER.
The printer displays 
PASSWORD
 and the number 
0000
.
2.
Enter the four-digit password for the password level displayed or for a higher level.
The left and right arrows change the selected digit position.
The up and down arrows change the value of the selected digit.
3.
After entering the password, press ENTER.
If you entered a valid password, additional parameters are displayed.
Table 7 • Password Levels and Defaults
Password 
Level
Features Controlled
Default Password
4
All features, including sensor adjustments 
and other sensitive parameters
For advanced use only. See the 
Maintenance Manual or contact 
technical support.
3
Installation and reconfiguration. The printer 
web-page interface also uses this password.
1234
2
Label configuration operations (media type, 
label removal method, label length)
0000
 (unprotected)
1
Darkness, Tear-Off position, label top
0000
 (unprotected)