Routine Maintenance
Lubrication
78
13290L-001 Rev. A
S4M User Guide
10/21/05
Lubrication
No lubrication is needed for this printer.
Cleaning Procedures
Specific cleaning procedures are provided on the following pages. 
 shows the 
recommended cleaning schedule.
Clean the Exterior
You may clean the exterior surfaces of the printer with a lint-free cloth and a small amount of a 
mild detergent, if necessary. Do not use harsh or abrasive cleaning agents or solvents.
Caution • 
Some commercially available lubricants will damage the finish and the 
mechanical parts if used on this printer.
Important • 
Zebra is not responsible for damage caused by the use of cleaning fluids on this 
printer.
Table 13 • Recommended Cleaning Schedule
Area
Method
Interval
Printhead
Solvent*
Direct Thermal Mode: After every roll of 
media (or 500 feet of fanfold media).
Thermal Transfer Mode: After every roll of 
ribbon or three rolls of media.
These intervals are intended as guidelines only. 
You may have to clean more often, depending 
upon your application and media.
Platen roller
Solvent*
Media sensors
Air blow
Ribbon sensor
Air blow
Media path
Solvent*
Ribbon path
Solvent*
Pinch roller. (part of Peel-Off option)
Solvent*
Tear-off/peel-off bar
Solvent*
Once a month.
Take label sensor
Air blow
Once every six months.
* Zebra recommends using Preventive Maintenance Kit (part number 47362) or a solution of 90% Isopropyl and 
10% deionized water)