Справочник Пользователя для Psion Teklogix PX750

Скачать
Страница из 238
158
Psion Teklogix NEO Hand-Held Computer User Manual
Chapter 5: Configuration
Decoded (ISCP)
Transmit Check Digit
If the check digit is to be transmitted with the data, this parameter must be enabled.
Transmit Number System
If this parameter is enabled, the number system digit is transmitted with the decoded bar 
code data.
Convert To UPC-A
This parameter converts UPC E (zero suppressed) decoded data to UPC A format before 
transmission. After conversion, data follows UPC A format and is affected by UPC A pro-
gramming selections (e.g. Check Digit).
Add/Remove Data
Refer to “Add/Remove Data” on page 142 for details. 
5.13.3.9 UPC/EAN Shared Settings
The setting assigned to the “Addendum” parameter associated with this option is shared 
across all UPC and EAN bar codes.
Addendum
An addendum is a separate bar code, supplementary to the main bar code. This parameter 
provides two options: Not Required but Transmitted if Read or Required and Transmitted
Double-tap on Addendum to display a dialog box listing your options.
Highlight an item, and tap on OK.
When “Addendum” is set to Not Required but Transmitted if Read, the scanner searches for 
an addendum and if one exists, appends it to the main bar code. When the parameter is set to 
Required and Transmitted, the scanner does not accept the main bar code without 
an addendum.
Addendum Add-on 2 And Addendum Add-on 5
Enabling these parameters sets the length of the addendum bar code to either 2 or 
5 characters.
GTIN Compliant
GTIN (global trade item number) processing transmits EAN 128 as the 14-character 
EAN/UCC GTIN. To use GTIN processing, you must activate the EAN 128 symbology.