Connecting 
 
6.2 Connecting the 100 V to 240 V AC power supply 
 
SIMATIC Panel PC 877 
6-4
 
Operating instructions, Release 07/2006, A5E00877780-01 
6.2 
6.2 
Connecting the 100 V to 240 V AC power supply 
General connection information 
Note the following in order to operate the device safely and according to regulation: 
 
 
Note 
Voltage range 
The power supply module is designed for operation on 100 to 240 V AC networks. The 
device adjusts automatically to the voltage. 
 
 
Notice 
Risk of damage 
Do not connect or disconnect power and data cables during thunderstorms. 
 
 
Notice 
Power supply network 
The device is designed for operation on grounded power supply networks (TN systems to 
VDE 0100, Part 300, or IEC 60364-3).  
It is not permissible for operation on ungrounded or impedance-grounded power networks 
(IT networks). 
 
 
Notice 
Permitted mains voltage 
The local rated voltage must be within the voltage range of the device. 
 
 
Notice 
Power disconnection 
The built-in switch does not disconnect the device from mains. The mains connector on the 
device must be disconnected to fully isolate the device from mains. The mains connector 
must be easily accessible. 
If this cannot be guaranteed, in cabinet installation, for example, or the mains connector 
clamp is used, an easily accessible power switch must be built into the device.