Справочник Пользователя для Mitsubishi Electronics CR751-D

Скачать
Страница из 190
6Safety
   
EMC installation guideline
   6-154
6.4 EMC installation guideline
6.4.1 Outlines
The EMC directive is coerced from January 1, 1996, and it is necessary to attach the CE mark which shows that 
the product is in conformity to directive.
Since the industrial robot is the component of the automation system, it considers that the EMC directive is not 
the target product of the direct. However, because it is one of the main components, introduces the method and 
components of the measures for conforming the automation system to the EMC directive.
And also we are carrying out the qualification test about the conformity of the EMC directive under the environ
-
ment based on the contents of this document. However, the noise level is changed by the kind of equipment to be 
used, the layout, the construction of the controlling board, the course of wiring, etc. Therefore, please confirm by 
the customer eventually.
6.4.2 EMC directive
The Mitsubishi Electric industrial robot follows the European EMC directive. This technical standard regulates the 
following two items.
(1) Emission (EMI : Electromagnetic Interference) ..............The capacity not to generate the disturbance noise 
which has a bad influence outside.
(2) Immunity (EMS : Electromagnetic Susceptibility)..........The capacity which does not malfunction for the dis
-
turbance noise from the outside.
Each contents are shown below.
Item
Name
Contents
Testing technical-
standard number
Emission
(EMI)
Radiative noise disturbance
The electromagnetic noise etc. which are emitted to 
environs.
EN61000-6-2 : 2005
EN61000-6-4 : 2007
EN62061:2005(Annex E)
Electrical-conduction noise disturbance
The electromagnetism noise etc. which flow out of 
the power-supply line.
Immunity
(EMS)
Electrostatic discharge immunity test
The noise from the electrified human body.
Radiated, radio-frequency, electromagnetic 
field immunity test susceptibility test
The electromagnetism noise from the transceiver, 
the broadcasting station, etc.
Electrical fast transient burst immunity 
test
The relay noise or the electromagnetism noise etc. 
which are caused in power-supply ON/OFF.
Immunity to conducted distrurbances 
induced radio-frequency fields
The electromagnetism noise etc. which flow in 
through the power source wire and the grounding 
wire.
Power frequency magnetic field immunity 
test
The electromagnetism noise with a power supply 
frequency of 50/60 Hz etc.
Voltage dips, short interruptions and 
voltage variations immunity test
The noise in the variation of the source voltage of 
the power dispatching, etc.
Surge immunity test
The electromagnetism noise by the thunderbolt, etc.