Справочник Пользователя для Toshiba 960-498
3 Tests and Diagnostics
3.22 Log Utilities
3.22.2 Operations
1. Select
5
and press
Enter
in the DIAGNOSTIC MENU, the error information is
displayed in the following format:
XXXXX ERRORS
CNT TS-NO PASS
STS ADDR
WD
RD HSTS [ERROR STATUS NAME]
001 FDD 02 0000 103 00001 00 00 0000 FDD-WRITE PROTECTED
001 FDD
01 0000 180 00001 00
00 0000 FDD-TIME OUT ERROR
Error count
Pass count
Error status
Address
Subtest number
Test name
[[1:Next,2:Prev,3:Exit,4:Clear,5:Print,6:FD Log Read,7:FD Log Write]]
2. The error information displayed on the screen can be manipulated by the following
number keys:
The
1
key scrolls the display to the next page.
The
2
key scrolls the display to the previous page.
The
3
key returns to the Diagnostic Menu.
The
4
key erases all error log information in RAM.
The
5
key outputs the error log information to a printer.
The
6
key reads the log information from a floppy disk.
The
7
key writes the log information to a floppy disk.
3. In the case of “error retry OK,” a capital “R” will be placed at the beginning of the
error status. However, it is not added to the error count.
Error status name
Read data
Write data
HDC status
QOSMIO F10 Maintenance Manual (960-498)
3-49