Справочник Пользователя для Fujitsu BS2OSD

Скачать
Страница из 47
 
Page 42
For BCAM problems: 
- activate all DCM traces with /DCDIAG DCM.,MODE=SAVE and 
  after reproducing the error, save the generated trace 
  files S.DCTRAC.* with /DCDIAG DCM.,MODE=CLOSE or submit 
  the diagnostic information to main memory with 
  /DCDIAG DCM.,MODE=HOLD  and evaluate it with ASTRID. 
 
For problems at the hardware and software interface: 
- HERSFILE 
- Hardware and software configuration 
- possibly IOTRACE listing. 
 
For tape problems: 
- if possible you should send in the original tape for 
  error diagnosis, otherwise you should at least provide 
  a listing of all tape labels and the first data blocks 
- SYSOUT log and CONSLOG file 
 
For SPD problems: 
- dump of the VTOC area 
- NDMDAMP 
- CONSLOG files of all systems involved 
 
  *4 
For IORM problems: 
  *4  
- IORM dump  
  *4 
 
- CONSLOG file  
  *4 
If problems occur with the IORM DPAV or IOLVM functions, under  
  *4 
VM operation these documents are required from both the guest  
  *4 
and the monitor system. 
 
 
Final note 
The above description does not contain any information on gener-
ating documents in conjunction with using BS2000 tracers. Please 
consult the reference manuals of the relevant tracers for this.