Справочник Пользователя для Acer X3910

Скачать
Страница из 96
Chapter 4
63
USB eModule Error Messages
SMBIOS eModule Error Messages
CPU eModule Error Messages
MPS Table (Multi-processor) eModule Error Messages
Message Displayed
Description
Warning! 
Unsupported USB 
device found and 
disabled!
This message is displayed when a non-bootable USB device is enumerated and 
disabled by the BIOS.
Warning! Port 60h/
64h emulation is not 
supported by this 
USB Host Controller!
This message is displayed to indicate that port 60h/64h emulation mode cannot be 
enabled for this USB host controller. This condition occurs if USB KBC emulation 
option is set for non-SMI mode.
Warning! EHCI 
controller disabled. It 
requires 64bit data 
support in the BIOS.
This message is displayed to indicate that EHCI controller is disabled because of 
incorrect data structure. This condition occur if the USB host controller needs 64-bit 
data structure while the USB is ported with 32-bit data structure.
Message Displayed
Description
Not enough space in 
Runtime area!!. 
SMBIOS data will not 
be available.
This message is displayed when the size of the SMBIOS data exceeds the 
available SMBIOS runtime storage size.
Message Displayed
Description
Warning! This system 
board does not 
support the power 
requirements of the 
installed processor. 
The processor will be 
run at a reduced 
frequency, which will 
impact system 
performance.
This message is displayed when the power requirements of the board do not match 
the power requirement of the CPU.
Message Displayed
Description
Insufficient Runtime 
space for MPS data! 
System may operate 
in PIC or Non-MPS 
mode.
This message is displayed when there is not enough space in the 0F000h runtime 
area for creating MPS table.