Справочник Пользователя для Acer Altos G710

Скачать
Страница из 198
 Appendix C: SCSI RAID configuration
160
If you change the settings in the Hot Spare field, the following 
messages appear:
WARNING: Data on drive will be LOST!
Press DELETE if data loss OK or any other key to 
cancel.
6
Press the Delete key to ignore. 
7
Press Esc, then select Save changes then exit this menu.
8
To close the utility and reboot the server, follow the steps below:
(1) Press Esc, then select Exit the Configuration Utility
The Global properties saved. Hit any key to 
reboot
 message appears.  
(2) Press any key to reboot the server.
RAID volume initialization
After you create the RAID volume and saved the changes, the disk 
controller will automatically initialize the RAID volume. LSI Logic 
53C1030 supports background initialization, there’s no need to wait 
for the initialization to complete. Close the LSI Logic Configuration 
Utility after saving the changes. 
Using the MegaRAID configuration utility
Turn on the system. When prompted, press Ctrl+M to enter the 
MegaRAID configuration utility. After a few seconds, the Management 
menu appears.
Loading the RAID card default setting
1
In the Management menu, select Objects, then select Adapter
The current adapter settings appear. 
2
Select Factory Default, then Yes to load the default settings. 
3
Press Ctrl+Alt+Del to reboot the server.