Справочник Пользователя для Emerson AXP1600
![Emerson](https://files.manualsbrain.com/attachments/1ef3aaad462e024fde6cecf537a4c6c781334d44/common/fit/150/50/6dab323528eefa0342baa74a10c15551c3b956250cf9d62f2117dcdf42a7/brand_logo.jpeg)
Power Entry Module Analog Sensors
FRU Information and Sensor Data Records
AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
127
2.5.5.1
Voltage Sensors
The following sensors measure voltages of the PEM.
Table 2-135 Sensor No. 2 +3.3 V
Feature
Raw Value/Description
Interpreted Value
Sensor Name
+3.3 V
Device
Sensor Type
0x02
Voltage
Class
0x01
Threshold
Sensor Owner LUN
0x00
Entity ID
0x0A
Power Supply
Entity Instance
0x60
Rearm mode
Auto
Hysteresis support
Readable/Settable
Threshold access support
Readable/Settable
Event message control
Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
Settable threshold mask (bytes
19, 20)
0x3F, 0x3F
Upper and Lower Non-Critical,
Critical and Non-Recoverable
Thresholds are Readable and
Settable
Critical and Non-Recoverable
Thresholds are Readable and
Settable
Reading Type
Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
Non-Recoverable thresholds
0xD8, 0xD4, 0xD1
(3.1104, 2.0528, 3.0096) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
Non-Recoverable thresholds
0xF4, 0xF7, 0xFA
(3.5136, 3.5568, 3.6) Volts
Table 2-136 Sensor No. 3 +8 V
Feature
Raw Value/Description
Interpreted Value
Sensor Name
+8 V Backup Out
Device
Sensor Type
0x02
Voltage
Class
0x01
Threshold
Sensor Owner LUN
0x00
Entity ID
0x0A
Power Supply
Entity Instance
0x60
Rearm mode
Auto
Hysteresis support
Readable/Settable
Threshold access support
Readable/Settable
Event message control
Entire Sensor only