Справочник Пользователя для Emerson AXP1600

Скачать
Страница из 148
AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
System Behavior in Response to Sensor Events
FRU State Management
144
   
A.5
FRU State Management
The following table provides the SAM action, FRU status, hot swap state for each FRU 
temperature sensor in the shelf.
Table A-1 FRU State Table for Nonrecoverable Threshold Events from Temperature Sensors
FRU
Temperature Sensor
SAM Action
FRU Status
Step-1
Step-2
Operation
Hot Swap 
State
H/S LED
Active 
SAM
Sensor # 6("MAX6656 INT 
@1A") 
Sensor # 7("MAX6656 EXT1 
@1A")  
Sensor # 8("MAX6656 EXT2 
@1A")
Set all FAN-
module speed 
MAX
 H/S 
LED 
ON. Still 
working as 
Active.
M6->M1 
(Logical 
SAM 
(0x20) will 
show M4 
state)
Turn ON
Standby 
SAM 
Sensor # 6("MAX6656 INT 
@1A") 
Sensor # 7("MAX6656 EXT1 
@1A") 
 Sensor # 8("MAX6656 EXT2 
@1A")
Set all FAN-
module speed 
MAX
 H/S 
LED 
ON.
M6->M1
Turn ON
PEM
Sensor # 12 ("DS75 Temp")
Set all FAN-
module speed 
MAX
Issue 
"deactivate" 
command to 
PEM
Still working. M6 > M1
Turn ON
ATCA-
F101
Sensor # 8 ("Inlet Temp")
Set all FAN-
module speed 
MAX
Issue 
"deactivate" 
command to 
F101
Payload 
powered 
down by the 
SAM.
M6 > M1
Turn ON
Sensor # 9 ("Outlet Temp")
Set all FAN-
module speed 
MAX
Issue 
"deactivate" 
command to 
F101
Payload 
powered 
down by the 
SAM.
M6 > M1
Turn ON
Sensor # 10 ("PMC Temp")
Set all FAN-
module speed 
MAX
Issue 
"deactivate" 
command to 
F101
Payload 
powered 
down by the 
SAM.
M6 > M1
Turn ON
Sensor # 20 ("Artesyn Temp")
Set all FAN-
module speed 
MAX
Issue 
"deactivate" 
command to 
F101
Payload 
powered 
down by the 
SAM.
M6 > M1
Turn ON