Справочник Пользователя для Belkin AVU1500

Скачать
Страница из 138
B
elkin 
Pur
eA
Hybrid 
A
VU1500 
UP
S
60
®
®
Using Your AVU1500 with a  
Home Automation System (optional)
•   Stage 1 Battery Threshold: default 90%, range from  
Stage 2 to 100%.
•   Stage 2 Battery Threshold: default 50%, range from  
Stage 3 to Stage 1.
•  Stage 3 Battery Threshold: default 0%, range from 0% to Stage 2.
•  Site Wiring Fault: 0: Wiring OK, 1: Wiring Fault.
•  Site Ground Fault: 0: Ground OK, 1: Ground Fault.
•  Shutdown Override: 1: Disable, 2: Enable.
•  IR Shutdown Code Known: 0: Unknown, 1: Learned.
•  Source Change: 0: Backup ¬ AC, 1: AC ¬ Backup.
•  Stage 1 startup/shutdown: 0: Startup, 1: Shutdown.
•  Stage 2 startup/shutdown: 0: Startup, 1: Shutdown.
•  Stage 3 startup/shutdown: 0: Startup, 1: Shutdown.
•  Overload: 0: Not overload, 1: Overload.
•  Battery Fully Charged: 0: Not fully charged, 1: Fully charged.
•   Battery Need Replacement: 0: Battery OK, 1: Battery  
need replacement.
•  Power Off: 0: UPS power on, 1: UPS power off.