Справочник Пользователя для Dukane 403-575-00

Скачать
Страница из 136
Lockout/Tagout   
 
Procedure to use BEFORE making any internal 
adjustments to the generator:
1.  Push the generator's AC power switch/breaker 
to the OFF position.
2.  Unplug the generator's electrical cord from its 
source.
3.  Authorized personnel apply a lockout/
tagout (LOTO) device to the plug end of the 
generator's electrical cord. Using a typical clam 
shell type LOTO device:
 
1)  Open the clam shell.
 
2)  Place the electrical cord plug end inside the  
 shell.
 
3)  Close the shell.
 
4)  Secure the shell with its lock, and lock it.
4.  Wait a minimum of five minutes for the 
generator to discharge its electrical energy.
5.  After taking these steps, make the necessary 
adjustments to the generator.
Assuming the generator is being put back into 
service. . . 
Procedure to use AFTER making any internal 
adjustments to the generator:
1.  Authorized personnel remove the lockout/
tagout device from the plug end of the 
generator's electrical cord. Using a typical clam 
shell type LOTO device:
  1)  Unlock the protective shell.
  2)  Open the shell, exposing the electrical cord  
 end.
  3)  Remove the LOTO device, and set it aside.
2.  Plug the generator's electrical cord into its AC 
power source.
3.  Push the generator's AC power switch/breaker 
to the ON position.
Continued from previous page
Page 14 
iQ  Series
 Ultrasonic Generator/Power Supply ES User’s Manual
Dukane Manual Part No. 403-575-00