Pneumatic Step 9 - Process Settings > Pressure 
Figure 4-34
 
iQ Explorer > Process Settings > Post Weld > Pressure
For systems equipped with the Electronic Pressure 
Regulator option, weld pressure parameters need to be 
programmed in this section of the Process Settings 
page. See Figure 4-34.
Downstroke
 - This is the approach pressure before 
Trigger. For a basic setup, program a value here equal to 
Pressure 1.
Weld Pressure 1
 - Program a pressure value based 
on the force requirement suggested in the Initial Weld 
Force chart. See Table 4-I and Figure 4-35
.
NOTE
Downstroke pressure must be pro-
grammed so that enough force will be 
available to achieve the programmed 
Trigger Force. If there is not enough 
downstroke pressure, it may cause the 
system to fault at Max Trigger Time.
Continued
Figure 4-35
 
Suggested Initial Weld Force
500
450
400
360
340
320
300
280
260
240
220
200
180
160
140
120
100
80
60
40
20
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
Fo
rce (pounds)
Linear Weld Joint  (inches)
0         2         4         6         8         10       12        14       16       18       20       22       24       26       28       30       32       34       36
500
150 
400
360
340
320
300
280
260
240
220
200
180
160
140
120
100
80
60
40
20
0
Page 62 
iQ  Series
 Ultrasonic Generator/Power Supply ES User’s Manual
Dukane Manual Part No. 403-575-00