Справочник Пользователя для Panasonic MDDDT5540P

Скачать
Страница из 133
- 64 -
Protection
*  Encoder  A/
B-phase
error
*  Encoder
communication
error
*  Encoder
connection
error
*  Encoder
communication
data  error
P o s i t i o n
error
O v e r - s p e e d
error
Command
pulse  sealer
error
Protective  Functions
Alarm
Code No.
2 0
2 1
2 2
2 3
2 4
2 6
2 7
C o u n t e r m e a s u r e s
Correct  the  encoder  wiring  per  the  wiring
diagram.  Correct  the  connection  of  the
pins.
Make  sure  that  the  power  of  the  encoder
is 5VDC  ±5% (4.75 to 5.25V). Especially when
the wire length is long, it is important to meet
this requirement. You should not bundle the en-
coder wires and motor wires together. Connect
the shield to FG. See the encoder wiring dia-
gram.
1) Check whether the motor operates per
the position command pulse or not. See
the torque monitor to check if the output
torque is saturated. Readjust the gains.
Maximize the value of Pr5E (torque limit
set-up). Correct the encoder wiring per
the wiring diagram. Increase the accel-
eration and deceleration time. Reduce
the load and velocity.
2) Increase the value of Pr63.
Do not give excessive speed commands. Check
the frequency of the command pulse and scale
ratio. If an overshoot occurs due to wrong gain
adjustment, readjust the gains. Correct the en-
coder wiring per the wiring diagram.
Check  the  set  values  of  Pr46  through  4B.
A d j u s t   t h e   s c a l e   r a t i o   s o   t h a t   t h e   f r e -
quency  of  the  command  pulse  may  be
500  kpps  or  less.
C a u s e
No  encoder  A-  and  B-phase  pulse  is  de-
tected.  The  encoder  failed.
Due  to  no  communication  between  the
encoder  and  amplifier,  the  detective  func-
tion  for  broken  encoder  wires  is  activated.
The  connection  between  the  encoder  and
amplifier  is  broken.
The  encoder  sends  an  erroneous  data
mainly  due  to  noises.  The  encoder  is  con-
nected  correctly,  though  the  data  is  not
correct.
The  position  error  pulse  is  larger  than
Pr63 (position error limit).
1) Operation of the motor does not follow the
commands.
2) Pr63 value (Position error limit) is smaller.
]
The motor velocity exceeds the specified limit.
The scale ratios set by Pr46 through Pr4B (nu-
merator of 1st to 4th command scale) are not
correct.