Справочник Пользователя для Panasonic A4P Series

Скачать
Страница из 232
210
Permissible Load at Output Shaft
50W, 100W
200W, 400W
750W
1kW
1.5kW to 3.0kW
4.0kW to 5.0kW
100W
200W, 400W
1.0kW to 2.0kW
3.0kW
4.0kW
5.0kW
500W to 1.5kW
2.0kW to 5.0kW
400W
1.5kW
2.5kW, 4.5kW
900W
2.0kW
3.0kW, 4.5kW
MSMD
MSMA
MQMA
MDMA
MHMA
MFMA
MGMA
Motor
series
Motor output
Radial thrust
Radial thrust
Thrust load A
and B-direction
During running
At assembly
Thrust load
A-direction
B-direction
147
392
686
686
980
147
392
980
1666
980
1666
980
1862
980
1666
2058
88
147
294
392
588
88
147
588
784
588
784
588
686
588
784
980
117.6
196
392
490
686
117.6
196
686
980
686
980
686
980
1176
68.6
245
392
392
490
784
68.6
245
490
784
490
784
392
490
784
686
1176
1470
58.8
98
147
147
196
343
58.8
98
196
343
196
343
147
196
294
196
490
50W
100W
200W
400W
750W
MSMD
Motor
series
Motor
output
Formula of Load and
load point relation
P =
3533
L+39
Unit : N (1kgf=9.8N)
L
P
<Note>
When the load point varies, calculate the permissible radial 
load, P (N) from the distance of the load point, L (mm) from 
the mounting flange based on the formula of the right table, 
and make it smaller than the calculated result.
P =
4905
L+59
P =
14945
L+46
P =
19723
L+65.5
P =
37044
L+77
L
L/2
P
A
M
B
Radial load (P) direction