Справочник Пользователя для Micro Technic PV-1075

Скачать
Страница из 9
Users Manual & Installation Guide  
 PV- 1075: N
I
MH
 BATTERY PACK WITH CHARGER
 
 
 
Page 7 of 9 
Battery connector (J1) 
The NiMH battery is connected to PV-1075 using J1 that is a two-pole MOLEX connector. The 
battery connector is disconnected at delivery to prevent deep discharge of the battery when not used 
for a longer period.   
PC/104 connector (CN1) 
PV-1075 is attached the PC/104 stack using CN1. There are no electrical connection to this 
connector and serves only to bypass the PC/104-bus in the stack. 
 
Battery charger 
The battery charger controls the charging process using two modes:  
•  standard charge mode with charging current = 50mA and 
•  trickle charge mode with charging current = 25mA. 
The switching between these modes is determined by a counter which is controlled by the 
‘presence’ of mains. There are two input frequencies to this counter: one used during the presence 
of mains input and one used when there are no mains input. The two frequencies have a mutual 
ratio of 32 where the lowest frequency is used during count-up. During the presence of mains, the 
counter counts up. When mains disappear, the counter counts down. The charging progress is 
illustrated below: 
 
Charging indicators 
Two LEDs indicate the actual charging mode: D4 (yellow) indicate Standard Charge and D9 
(green) indicate Trickle Charge. These LEDs are located on the component side.