Справочник Пользователя для Micro Technic PV-1800

Скачать
Страница из 19
Users Manual & Installation Guide  
                            PV- 1800: Power supply module with GSM MODEM 
 
 
Page 19 / 19 
Installation guide 
Precautions to ESD 
Please note that the Micronix PV modules must be handled with respect to ESD (Electrostatic 
Discharge).  Electrostatic Discharge to the PV modules must be avoided.  
Before removing the module from the protection bag, the user must be discharged using a grounded 
wrist ribbon. 
 
Settings and connections 
A typical setup procedure involves these steps: 
1.
  Perform settings of: 
•  Base address. (Regs.). 
•  Port number for COM_A (modem). 
•  IRQ number COM_A (modem). 
•  Port number for COM_B (RS232). 
•  IRQ number for COM_B (RS232). 
 
2.
  Place PV1800 in the PC/104 stack. 
3.
  Connect interface cables: Analogue, digital etc. 
4.
  Place a SIM card in the SIM card connector. 
5.
  Connect the antenna cable to the MMCX-connector at the modem. 
6.
  Connect the power cable (24V DC) at KL1. 
 
Factory settings 
The default jumper setting depends on the model you have purchased. 
 
Factory settings, PV-1800: 
 
 
Registers base address: 200h 
Modem port: 3E8 (COM3) 
Modem IRQ: 10 
RS232 port: 2E8 (COM4) 
RS232 IRQ: 12 
 
 
 
Factory settings, PV-1820 / PV-1830: 
 
 
Registers base address: 200h 
Modem port: 3E8 (COM3) 
Modem IRQ: 10 
 
+
,- 
,-#
.
%- 
%-#
'$
 
+
,- 
,-#
.
%- 
%-#
'$