Справочник Пользователя для Mitsubishi Electronics 700 Series

Скачать
Страница из 183
13
Device Map
1
D
e
vi
ce
 M
a
p
M9211
Inverter operation status 
control flag (RES)
Control the RES terminal of the inverter from PLC 
function
M9216
Inverter status (RUN)
Inverter running
M9217
Inverter status (FWD)
Forward running
M9218
Inverter status (REV)
Reverse running
M9219
Inverter status (SU)
Up to frequency
M9220
Inverter status (OL)
Overload alarm
M9221
Inverter status (IPF)
Instantaneous power failure/undervoltage
M9222
Inverter status (FU)
Output frequency detection
M9223
Inverter status (ALM)
Alarm output
M9224
Inverter status (LF)
Minor fault output
M9225
Inverter status (DO0)
Status of output terminal function set in Pr. 313 is stored *1
M9226
Inverter status (DO1)
Status of output terminal function set in Pr. 314 is stored *1
M9227
Inverter status (DO2)
Status of output terminal function set in Pr. 315 is stored *1
M9228
Inverter status (DO3)
Status of output terminal function set in Pr. 316 is stored *1
M9229
Inverter status (DO4)
Status of output terminal function set in Pr. 317 is stored *1
M9230
Inverter status (DO5)
Status of output terminal function set in Pr. 318 is stored *1
M9231
Inverter status (DO6)
Status of output terminal function set in Pr. 319 is stored *1
M9232
Inverter status (RA1)
Status of output terminal function set in Pr. 320 is stored *1
M9233
Inverter status (RA2)
Status of output terminal function set in Pr. 321 is stored *1
M9234
Inverter status (RA3)
Status of output terminal function set in Pr. 322 is stored *1
M9255
Inverter operation status 
control selection
Select the inverter status control command from M9200 
to M9211 or D9148.
OFF: Special relay selection
ON  : Special register selection
*1. Even if the FR-A7AY, FR-A7AR is not mounted, Pr. 313 to Pr. 322 are accessible during
PLC function operation, and status of output terminal functions are stored in each device.
(virtual output terminal)
Number
Name
Description