Справочник Пользователя для Mitsubishi Electronics 700 Series

Скачать
Страница из 183
37
Inverter Parameter Read/Write Method
1
Inverter parameter data write timing chart
Y29(Y2B)
X29(X2B)
Parameter 
write completion
Inverter parameter
D9242(D9244)
Parameter write
data
User sequence
data
Parameter
write command
1) In user sequence, user data
    are stored into parameter write
    data area (D9242(D9244)).
2) Write command is turned
    on in user sequence.
4) After confirmation of write
    completion, write command 
    is turned off.
3) Turns on when inverter CPU completes inverter
    parameter data write.
    0 written to D9150 indicates normal completion.
    Any value other than 0 indicates abnormal completion.
5) Inverter CPU confirms
    that write command is 
    off and turns off write
    completion.