Chapter 31
31-4
Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
set temperature (warning)
Command Mode
Global Configuration. 
Description
Sets the warning temperature (in Celsius) for a specific component of the 
switch. The default values are listed in 
Syntax
set temperature {supervisor-slot | backplane-sensor | cpu-sensor | probe} 
warning {upper | lower | low-limit} <temperature>
Table 31-3.  Default Warning Temperatures
Component
Upper 
Warning
Lower 
Warning
Low Limit
 CPU Sensor
85°
 All others
60°
Table 31-4.  Parameters, Keywords, Arguments
Name
Definition
{supervisor-slot | 
backplane-sensor | 
cpu-sensor | probe} 
Indicates which component of the switch you are setting 
the temperature for. 
Note:
After you change the temperature settings for the 
active supervisor, you must synchronize the active 
and standby supervisors to copy the temperature 
settings to the standby supervisor.  
warning
Required parameter indicating that a warning limit is 
being modified.
1 of 2