Maintenance
TEMP, LAMP and ARF Indicators
If a problem should occur with the projector, the TEMP , LAMP and/or 
FILTER indicators will inform you. Manage the indicated problems as 
follow.
1. Confirm the status of all indicators and projector, and switch off the 
projector in proper way.
2. Find out the cause of the problem by status of the TEMP , LAMP 
and/or FILTER indicators.
3. Follow the instruction for each indication below and solve the 
problem.
4. Turn on the projector in the correct way and confirm the indicator is 
not indicating a problem any longer.
J
LAMP indicator
J
TEMP indicator
J
FILTER indicator
When the ARF indicator is flashing GREEN, the ARF is normally rolling up.
Managing the indicated problems
NOTE:
• If no problem is found or the problem remains, do not turn on the projector. Instead contact an Authorized Service Center.
Indicator
 
Illuminating RED
 
Flashing RED
Problem
LAMP RUNTIME has 
reached 2 800 hours.
LAMP circuit failure, abnormal function or Lamp unit is damaged.
Cause
Lamp unit will run out 
soon and needs to be 
replaced.
The MAIN POWER is 
switched on again 
before the Lamp unit 
is cooled enough.
LAMP circuit failure, 
abnormal function.
Lamp unit is 
damaged.
Remedy
Let the Lamp unit cool 
down and turn on the 
MAIN POWER.
Contact an Authorized 
Service Center.
Indicator
 
Illuminating RED and still projecting
 
Flashing RED and POWER is turned off
Problem
The temperature inside and/or outside the projector is abnormally high.
Cause
The ventilation 
openings are covered.
The room temperature 
is too high.
The ARFis excessively 
dirty and the ventilation 
is poor.
The projector is located 
at high elevations 
(above 1 400 m).
Remedy
Remove the object(s) 
from the ventilation 
openings or clear 
around the projector.
Reinstall the t a 
temperature controlled 
place. See page 16.
Replace the ARF in the 
proper method. See 
page 42.
Turn on the projector
*1
 
and set the 
HIGHLAND to ON
See page 38.
*1. The projector will perform only 2 minutes with OFF setting at high elevation.
Indicator
 
Illuminating RED
 
Flashing RED
 
Illuminating ORANGE
 
Flashing ORANGE
Problem
FILTER REMAINING 
has turned red. See 
page 37.
The projector cannot 
detect the ARF.
The ARF cannot 
operate properly.
FILTER REMAINING 
has turned yellow. See 
page 37.
Cause
ARF has been run out. ARF is not attached.
Foreign object is 
blocking the ARF 
operation.
ARF is running out.
Remedy
Attach the ARF.
Remove the foreign 
object or contact an 
Authorized Center.
Prepare the ARF for 
replacement.
POWER LAMP