Справочник Пользователя для Mitsubishi Electronics XL50

Скачать
Страница из 120
 
 
 
PH50, XL50, XL21 series Set-up and Installation Manual 
 
16 
X
X
L
L
5
5
0
0
 
X
X
L
L
2
2
1
1
 
1.2.6.3.2. For 
5
5
0
0
S
S
i
i
n
n
g
g
l
l
e
e
 
According to circumstances, attach the optional external AC fans (JC-AF115R or JC-AF230R) on 
the intake vents in the bottom row (see “External AC fan attaching” on page 17)
•  Prepare openings on base stands to ventilate. 
•  Keep enough base stand height not to inhale a coat of dust on a floor from the intake vents. 
 
1.  To block the bottom row, detach the bottom duct cover from inside the cube and attach it on 
the bottom of the duct. Be sure this work is only for the cubes in the bottom row. 
2.  To block the top row, remove the cushion unit on the top at first. Then detach the top duct 
cover from the top surface of the cube and attach it on the top of the duct. Be sure this work 
is only for the cubes in the top row. 
 
 
 
 
 
 
3.  To keep dust out, seal the cable holes on the top of the display 
wall. Prepare a cover material by yourself. The size of the 
holes is 116.5mm x 63mm. Be sure this work is only for the 
cubes in the top row. 
 
 
 
 
 
 
 
Detaching 
Tighten the duct screw 
to attach with duct 
panel. 
Cable hole 
 
Detaching
Top duct cover 
Cushion unit 
Bottom duct cover 
Tighten removed screw 
to attach.
 
Detaching 
Tighten removed 3 
screws to attach.