1.6.5. Input 
memory 
saving 
The adjusted values can be saved in an input memory. The number of the memories is 128. 
Be sure to save when you change the values. Even if the same resolution has already registered 
in a memory, save the new adjusted values in another input memory if some menus such as 
FINE or POSITION have different values from the existing memory. 
[Procedure] 
1.  Press [ESC] button during the input memory menu displaying. In reply to “SAVE THE 
CHANGES?” message, press [ENTER] button. You can exit the menu by [ESC] button 
without saving. 
2.  Designate a memory number to save in by left/right buttons and press [ENTER] button. 
3.  The current setting will be saved in the memory if the number is unregistered. When it has 
already been registered, the overwrite confirmation message will be displayed. 
1.6.6. Input 
memory 
calling/deleting 
Registered input memories can be called or deleted when needed. 
• 
Call: Press [MEM LIST] button to select INPUT MEMORY. Designate a memory number to 
be called by left/right buttons and press [ENTER] button. 
• 
Delete: Press [MEM LIST] button to select INPUT MEMORY. Designate a memory number 
to be deleted by left/right buttons. Select DELETE MEMORY by up/down buttons and press 
[ENTER] button in reply to “DELETE OK?” message.