Справочник Пользователя для Mitsubishi Electronics XL50

Скачать
Страница из 120
 
 
 
PH50, XL50, XL21 series Set-up and Installation Manual 
 
60 
 
1.7.4.5. FRAME 
LOCK 
This adjustment is normally unnecessary. The optimum value is automatically set in 
automatic input signal scanning.
 
Used to set a frame lock. Set ON when frame tearing or field skips are noticeable in a moving 
image with 50 – 60 Hz of vertical frequency. 
• 
ON: External synchronization mode to synchronize the frame rate to the input signal. 
• 
OFF: Internal synchronization mode to convert the frame rate to an internal rate. 
[Procedure] 
1.  Select FRAME LOCK in the input memory menu (on the 1st menu sheet). 
2.  Select ON or OFF. 
1.7.4.6.  SCAN MODE (for S.ANALOG or S.DIGITAL input) 
This adjustment is normally unnecessary. The optimum value is automatically set in 
automatic input signal scanning.
 
Used to select a scan mode as needed when interlace signal is input. 
[Procedure] 
1.  Select SCAN MODE in the input memory menu (on the 1st menu sheet). 
2. INTERLACE 
adjustment 
• 
OFF: Select for a non-interlace signal. 
• 
STATIC: Select for an interlace signal for a still image. 
• 
MOTION: Select for an interlace signal for a motion image. 
Note: STATIC and MOTION menus are available only when an interlace signal is input from 
S.ANALOG or S.DIGITAL port. 
3. F-INVERT 
adjustment 
Used to inverse even/odd fields when cross lines on an image are jagged. It is available only 
when an interlace signal is input from S.ANALOG or S.DIGITAL port. 
• 
ON: Inversing even/odd fields when an interlace signal is input. 
• 
OFF: NOT inversing even/odd fields when an interlace signal is input. 
1.7.4.7.  SIGNAL SELECT (for COMPOSITE or Y/C input) 
This adjustment is normally unnecessary. The optimum 
value is automatically set in automatic input signal 
scanning.
 
Used to select a signal type according to an input signal when 
an incorrect image is displayed after automatic input signal 
scanning. 
In the case of S.ANALOG and S.DIGITAL input, SIGNAL 
SELECT menu cannot be adjusted. 
[Procedure] 
1.  Select SIGNAL SELECT in the input memory menu (on the 
1st menu sheet). 
2.  Select a correct input video signal type. If you select AUTO, the suitable signal is 
automatically set. 
SIGNAL SELECT 
 
AUTO 
NTSC 
PAL 
SECAM 
NTSC4.43 
PAL-M 
PAL-N 
PAL-60 
SIGNAL SELECT menu