5.6.6  SIGNAL menu
ITEM
Function
Data
Character
ASCII code
MEMORY CALL
MMC
4Dh  4Dh  43h
0 (AUTO), 1 to 8 (MEMORY 1 to 8)
HORIZ.POSITION
HP
48h  50h
+ (increment), - (decrement)
*1
VERT. POSITION
VP
56h  50h
+ (increment), - (decrement)
*1
FINE SYNC.
FN
46h  4Eh
00–31
TRACKING
TRK
54h  52h  4Bh
+ (increment), - (decrement)
*1
COMPUTER INPUT
CIN
43h  49h  4Eh
0 (RGB), 1 (YC
B
C
R
/YP
B
P
R
), 2 (AUTO)
OVER SCAN
VOS
56h  4Fh  53h
00 (90%) – 10 (100%)
HOLD
HLD
48h  4Ch  44h
0 (OFF), 1 (ON)
HOLD BEGIN
HLB
48h  4Ch  42h
00–99
HOLD END
HLE
48h  4Ch  45h
00–99
ASPECT
SC
53h  43h  
0 (NORMAL, 1 (16:9), 2 (NATIVE), 3 (FULL), 
4 (USER)
ASPECT-USER-
ZOOM(H)
ZMH
5Ah  4Dh  48h
050 to 500
NAK is returned when the ASPECT setting is other 
than USER.
ASPECT-USER-ZOOM(V)
ZMV
5Ah  4Dh  56h
050 to 500
NAK is returned when the ASPECT setting is other 
than USER.
ASPECT-USER-HORIZ. 
POSITION
AHP*
41h  48h  50h
*:+, -
+:incriment  -:decriment
NAK is returned when the ASPECT setting is other 
than USER.
ASPECT-USER-VERT. 
POSITION
AVP*
41h  56h  50h
*:+, -
+:incriment  -:decriment
NAK is returned when the ASPECT setting is other 
than USER.
ASPECT-USER-RASTER 
POSITION(H)
RPH*
52h  50h  48h
*:+, -
+:incriment  -:decriment
NAK is returned when the ASPECT setting is other 
than USER.
ASPECT-USER-RASTER 
POSITION(V)
RPV*
52h  50h  56h
*:+, -
+:incriment  -:decriment
NAK is returned when the ASPECT setting is other 
than USER.
ASPECT-USER-RESET
ASRST
41h  53h  52h  53h  54h
The setting contents of ASPECT USER are reset.
NAK is returned when the ASPECT setting is other 
than USER.
CLAMP POSITION
CLP
43h  4Ch  50h
001 to 255
CLAMP WIDTH
CLW
43h  4Ch  57h
01 to 63
VERT. SYNC.
VSC
56h  53h  43h
0 (AUTO), 1 (OFF)
LPF
LPF
4Ch  50h  46h
0 (OFF), 1 (ON)
SHUTTER(U)
SHU
53h  48h  55h
000 to 259
SHUTTER(L)
SHL
53h  48h  4Ch
000 to 259
SHUTTER(LS)
SHLS
53h  48h  4Ch  53h
000 to 311
SHUTTER(RS)
SHRS
53h  48h  52h  53h
000 to 311
*1) Setting range differs depending on the input signals.
5.6.7  NETWORK menu
ITEM
Function
Data
Character
ASCII code
PROJECTOR NAME
NAME
4Eh  41h  4Dh  45h
Up to 15 single-byte alphanumeric characters
Effective only during P-ON.
NETWORK RESTART
NRCN
4Eh  52h  43h  4Eh
LAN microcomputer is reset and restarted.
 •  Some commands are not executed depending on the input signal. The operational restrictions same as those 
on the menu setting are applied. Refer to “Menu operation” in the User Manual for more details.