Справочник Пользователя для Promise Technology m210p

Скачать
Страница из 262
VTrak M310p, M210p Product Manual
136
Blowers
This screen displays the status and speed of VTrak’s blowers. There is one 
blower in each cooling unit.
Blower status should be Functional
Healthy Threshold – Minimum acceptable fan speed
Current Speed – Should be greater than the Healthy Threshold value
If either blower speed is below the Healthy Threshold, there is a blower 
malfunction. See “Chapter 6: Maintenance” on page 167.
Voltage Sensors
There are three power supply circuits inside the VTrak.
Voltage Sensor – Circuits: 3.3V, 5.0V, 12V
Healthy Threshold – Normal voltage range for each circuit
Current Voltage – Should be within the Healthy Threshold values
If any voltage is outside the Healthy Threshold values, there is a voltage 
malfunction in the enclosure. See “Chapter 8: Troubleshooting” on page 203.
Temperature Sensors
The number and type of sensors depends on the VTrak model. Controller 
sensors normally run warmer than backplane sensors.
Sensor number
Location – Backplane or Controller
Healthy Threshold – Maximum acceptable temperatures.
Current Temperature – Should be less than the Healthy Threshold 
value.
If any temperature exceeds the Healthy Threshold value, there is an overheat 
condition in the enclosure. See “Chapter 8: Troubleshooting” on page 203.
Enclosure Settings
Enclosure settings include internal sensor polling intervals and temperature 
thresholds. To access Enclosure settings:
1.
From the Main Menu, highlight Subsystem Management and press Enter.
2.
Highlight Enclosure Management and press Enter.
3.
Highlight Enclosure Settings and press Enter.
From this point, you can make settings to the polling interval and 
temperature thresholds.