5. DRAIN CONNECTIONS - See Fig. 4
5. DRAIN CONNECTIONS - See Fig. 4
5. DRAIN CONNECTIONS - See Fig. 4
5. DRAIN CONNECTIONS - See Fig. 4
5. DRAIN CONNECTIONS - See Fig. 4
1. A drain outlet, 3/4" FPT, is located at the rear of the ice dispensing bin.
2. The drain must have 1/4" fall per foot on horizontal runs to get a good flow.
3. The ice dispensing bin drain connection must be made separately from the icemaker
    drains.  See the “WATER SUPPLY AND DRAIN CONNECTIONS” instructions on the
     icemaker.
4. A plumbing permit and services of a licensed plumber may be required in some areas.
6. FINAL CHECK LIST
6. FINAL CHECK LIST
6. FINAL CHECK LIST
6. FINAL CHECK LIST
6. FINAL CHECK LIST
 1) Is the icemaker/ice dispensing bin level?
 2) Is the icemaker/ice dispensing bin in a site where the ambient temperature is within
+45°F to +100°F all year around?
 3) Is there at least 6" (15 cm.) clearance around the icemaker/ice dispensing bin for easy
     maintenance and service, and for good ventilation?
 4) Have all shipping cartons, tapes and packing been removed from the icemaker/ice
     dispensing bin?
 5) Are all components, fasteners and thumbscrews securely in place?
 6) Have all electrical and piping connections been made?
 7)  Has the power supply voltage been checked or tested against the nameplate rating?
     Has a proper ground been installed in the icemaker/ice dispensing bin?
8) Has the ice dispensing bin been cleaned and wiped with a clean cloth?
9) Has the end user been given the instruction manual, and instructed on how to operate
     the icemaker/ice dispensing bin and the importance of the recommended periodic
     maintenance?
10) Has the end user been given the name and telephone number of the contracted  service
       representative?
11) Has the warranty tag been filled out and forwarded to the factory for warranty registration?