Справочник Пользователя для Pelco C578M-A

Скачать
Страница из 44
C578M-A (4/05)
19
DIP SWITCH SETTINGS
Some HS operating parameters are determined via two DIP switches, which are physically located to
the left of the front panel LED displays, but behind the front panel of the CCC itself. Figure 2-4 illus-
trates all DIP switch settings. Factory default is indicated.
ENABLED
(DEFAULT)
DISABLED
DIP SWITCH 1               DIP SWITCH 2
CM9760-CCC (FRONT PANEL)
LED OPENINGS
DIP
SWITCHES
FOLLOW
MASTER
(DEFAULT)
INDEPENDENT
OF MASTER
9600
(DEFAULT)
19200
31250
38400
SYNCH
(DEFAULT)
FAULT
RESPONSE
(DEFAULT)
ACTIVE
(DEFAULT)
INACTIVE
INACTIVE
(DEFAULT)
ACTIVE
RS-422
(DEFAULT)
RS-232
1
2
3    4
5
6
7
8
1    2
AUDIO SIGNAL
FOLLOW SWITCH
BAUD RATE
DEFAULT MODE
AUTO SWITCH
PRINTER
DIAGNOSTICS
COMM TYPE
LEGEND
     = ON OR UP
     = OFF OR DOWN
PWR
SYSTEM
SELECT
A
B
CC1
KVD
CM9760-CCC
HOT SWITCH
Made in USA
20068
DIP SWITCH 1
AUDIO SIGNAL
THIS TURNS OFF THE TONE (DIP 1-1, DOWN) HEARD WHENEVER A SYSTEM FAULT OCCURS. IT DOES NOT AFFECT THE TWO-BEEP TONE HEARD
WHEN A USER REASSERTS ASYNCHRONOUS MODE.
FOLLOW SWITCH
THE DIAGNOSTIC TOOLS ATTACHED TO CPS EQUIPMENT OUTPUT PORTS FOLLOW (DIP 1-2, UP) THE CC1 SWITCH IN CONTROL (MASTER) IF A
CHANGEOVER OCCURS.
BAUD RATE
THE BAUD RATE SELECTED HERE (9600 IS DEFAULT) AND THAT ENTERED INTO THE COMMS FILE FOR THE PORT TO WHICH THE CCC IS ATTACHED
MUST AGREE.
DEFAULT MODE
ALWAYS SET TO SYNCHRONOUS (DEFAULT = ON). OFF SETTING IS FOR FACTORY USE.
AUTO SWITCH
IF MASTER FAILS, SYSTEM WILL SWITCH TO SLAVE (DEFAULT = OFF). IF ON, SYSTEM WILL NOT SWITCH.
PRINTER
SET TO INACTIVE (DEFAULT). IF YOU CONNECT A PRINTER TO THE CCC LOGGING PRINTER PORT, SET THE SWITCH TO THE ACTIVE (DIP 1-8, UP)
POSITION. THE PRINTER PORT SUPPORTS DOT MATRIX PRINTERS CAPABLE OF IBM OR EPSON EMULATION MODES, SUCH AS THE OKIDATA 320
(NON-TURBO) AND THE OKIDATA 390 (TURBO) OR 391 (TURBO).
DIAGNOSTICS
DEFAULT IS ACTIVE. DIAGNOSTIC TOOLS SHOULD BE ACCESSIBLE.
DIP SWITCH 2
COM TYPE
SET TO CORRESPOND TO THE DATA COMMUNICATIONS TYPE CHOSEN. RS-422 IS THE DEFAULT.
Figure 2-4.  DIP Switch Configuration