Figure 47.  Access the Port Screen
SET SERIAL PORT:
Select the number of the desired Serial Port/COM port (01-10).
The serial port numbers correspond to the communication ports on
the CM6800 rear panel as follows:
Serial Port
Input on CM6800 rear panel
01
COM 1
NOTE:
  COM 1 can be accessed through a DB9
input or an RJ-45 port.
02-08
COM 2-8 RJ-45 inputs
09
PTZ-A control input
10
PTZ-B control input
DEVICE:
Select the device connected to the COM port; the values in the
TYPE, BAUD RATE, PARITY, DATA BITS,  and  STOP BITS fields
change to the settings appropriate for the specific device.
TYPE:
If necessary, and if allowed, select the desired communication type
(RS-232, RS-422, or RS-485).
BAUD RATE:
Select the desired baud rate.
PARITY:
Select the desired parity type.
DATA BITS:
This value cannot be changed.
STOP BITS:
This value cannot be changed.
PELCO SWITCHER
MODEL CM6800
MAIN MENU
1
CAMERA
2
LOGICAL CAMERA
3
MONITOR
4
ACCESS
5
TIME & DATE
6
PORT
7
PRIORITY
8
SEQUENCE
9
MACRO
10
ALARM CONTACTS
11
EVENT TIMER
12
SET AUXILIARY
13
SET PASSWORD
14
ABOUT CM6800
ENGLISH
RETURN
00654
SET SERIAL PORT 05
DEVICE:
KBD300
TYPE:
RS485
BAUD RATE:
9600
PARITY:
ODD
DATA BITS:
8
STOP BITS:
1
RETURN
00657
NOTE:
  In the programming
screens “KBD300” is used
to refer to the KBD100,
KBD200, and KBD300
keyboards.
PORTS (SERIAL/COM PORTS)
Use the Port screen to configure the settings for each device connected to a Serial/COM
port on the rear panel of the CM6800.