Справочник Пользователя для DAXTEN DSR1020

Скачать
Страница из 96
 Appendices        73
Appendix D: Using DSRIQ-SRL Modules
The DSRIQ-SRL module is a serial-to-VGA converter which permits VT100-capable devices to be 
viewed from the DSR switch local port or by using the DSView software. The actual serial data is 
not accessed, but is merely displayed. All serial data coming from the target device is displayed in a 
VT100 window, placed into a video buffer and sent to the DSR switch as though it came from a 
VGA target. Likewise, keystrokes entered on a keyboard are sent to the attached device as though 
they were typed upon a VT100 terminal.
DSRIQ-SRL module modes
The following modes can be accessed from the DSRIQ-SRL module:
On-Line: This mode enables you to send and receive serial data.
Configuration: This mode enables you to specify DSR switch communication parameters, the 
appearance of the Terminal Applications menu and key combinations for specific actions 
and macros.
History: This mode enables you to review serial data.
Configuring the DSRIQ-SRL module
NOTE: The DSRIQ-SRL module is a DCE device and only supports VT100 terminal emulation.
Pressing 
Ctrl-F8
 will activate the Configuration screen of the DSRIQ module’s Terminal 
Applications menu, which enables you to configure your DSRIQ-SRL module.
NOTE: When any Terminal Applications menu is active, pressing Enter saves changes and returns you to the 
previous screen. Pressing Escape returns you to the previous screen without saving changes.
Within the Terminal Applications menu’s Configuration screen, you can modify the 
following options:
Baud Rate: This option allows you to specify the serial port communications speed. Available 
options are 300, 1200, 2400, 9600, 19,200, 34,800, 57,600 or 115,200 bps. The default value 
is 9600.
Parity: This option allows you to specify the serial port’s communications parity. Available 
options are EVEN, ODD or NONE. The default value is NONE.
Flow Control: This option allows you to specify the type of serial flow control. Available 
options are NONE, XOn/XOff (software) and RTS/CTS (hardware). The default value 
is NONE. If you select a bps rate of 115,200, the only available flow control is 
RTS/CTS (hardware).
DSR/CD Mode: This option allows you to control how the DSR switch and CD lines operate. 
Available options are Always on and Toggle. When in Toggle mode, DSR and CD lines are 
turned off for one-half second and then turned on each time a module is selected or deselected. 
The default value is Always on.