Справочник Пользователя для Q-Logic 59022-03 D

Скачать
Страница из 168
4 – Managing Switches
Displaying Switch Information
4-2
59022-03 D
Figure 4-1.  Faceplate Display
The fabric updates the topology and faceplate displays by forwarding changes in 
status to the management workstation as they occur. You can allow the fabric to 
update the switch status, or you can refresh the display at any time. To refresh 
switch status in the display, do one of the following:
Choose the Refresh button.
Open the View menu and select Refresh.
Press the F5 key.
Right-click a switch in the topology display and select Refresh Switch from 
the popup menu.
Right-click in the graphic window of the faceplate display, and select 
Refresh Switch from the popup menu.
4.1.1
Displaying Hardware Status
A SANbox2 switch is equipped with the following chassis LEDs that provide 
hardware status information:
Chassis Over Temperature LED - indicates air temperature inside the 
switch.
Fan Fail LED - indicates operational status of both fans. 
Heartbeat LED - indicates the status of the internal switch processor and the 
results of Power On Self Tests (POSTs).
Input Power LED - indicates the voltage status at the switch logic circuitry.