2.3  Power Supply Wiring and Grounding 
The RSG2000 family supports dual redundant power supplies, “Power Supply 1” 
(PS1) and “Power Supply 2” (PS2). The connections for PS1, PS2 and the fail-
safe relay are located on the terminal block as shown in Figure 16 and Figure 17. 
RSG2000 products can be equipped with either a Philips Screw Terminal Block 
or a Phoenix Plug Terminal Block. The Philips Screw Terminal Block has Philips 
screws with compression plates, allowing either bare wire connections or 
crimped terminal lugs. We recommend the use of #6 size ring lugs to ensure 
secure, reliable connections under severe shock or vibration. Both terminal 
blocks have a safety cover which must be removed via two Phillips screws before 
connecting any wires.  The safety cover must be reattached after wiring to 
ensure personnel safety. Refer to Table 5 below for a description of each 
terminal as well as to sections 2.3.1 through 2.3.3 for power supply wiring 
examples. 
 
 
Figure 16: RSG2000 Series Philips Screw Terminal Block 
 
 
Figure 17: RSG2000 Series Phoenix Plug Terminal Block 
 