Positioning Your Hub
When installing your OfficeConnect hub, ensure:
It is out of direct sunlight and away from sources of 
heat.
Cabling is away from power lines, fluorescent lighting 
fixtures, and sources of electrical noise such as radios, 
transmitters and broadband amplifiers.
Water or moisture cannot enter the case of the unit.
Air flow around the unit and through the vents in the 
side of the case is not restricted. We recommend you 
provide a minimum of 25.4 mm (1in.) clearance.
Securing Your Hub
There are two slots on the underside of the OfficeConnect 
hub which can be used for wall mounting. It is 
recommended that you mount the hubs with the LEDs 
facing upwards to prevent dust entering the cooling vents.
 
When wall mounting the unit, ensure that it is within 
reach of the power outlet.
You need two suitable screws. Ensure that the wall you are 
going to use is smooth, flat, dry and sturdy. Make two 
screw holes which are 142mm (5.6in.) apart. Use the 
template at the back of this guide to mark the position of 
the holes. Fix the screws into the wall, leaving their heads 
3mm (0.12in.) clear of the wall surface.
Remove any connections to the unit and locate it over the 
screw heads. When in line, gently push the unit on to the 
wall and move it downwards to secure. When making 
connections, be careful not to push the unit up and off the 
wall.
CAUTION:  Only wall mount single units, do not wall 
mount stacked units.
Also available from 3Com, is the OfficeConnect Mounting 
Unit (part number 3C16765). This allows you to firmly 
secure a stack of OfficeConnect devices to the desktop or 
onto a shelf in a rack.