The Hub has been designed to aid you when 
detecting and solving possible problems with your 
network. These problems are rarely serious; the cause 
is usually a disconnected or damaged cable, or 
incorrect configuration. If this section does not solve 
your problem, contact your supplier for information 
on what to do next.
Perform these actions first:
Ensure all network equipment is powered on.
Power each piece of network equipment off, wait 
about 5 seconds and then power each one on.
Check the following symptoms and solutions:
Power LED not lit. Check your power adapter 
connection. If there is still no power, you may have a 
faulty power adapter which needs replacing with an 
identical OfficeConnect power adapter. Do not use 
any other power adapter with the Hub.
Port Status LED not lit for a port that has a 
connection.
 Check that you are using a 
‘straight-through’ cable which is properly connected 
at both ends, and is not damaged. Refer to “Twisted 
Pair (TP) Cables” on page 3.
 Also check that the 
equipment connected to the Hub is powered on, 
operating correctly and contains the correct type of 
connection.
Port Status LED lit yellow for a port with a 
100Mbps device connected.
 This may be because 
the cable is not of a high enough quality to carry Fast 
Ethernet signals (we recommend you use a 
Category 5 cable), or due to a problem with the 
network card (NIC) of the attached equipment.
Port Status LED flashing. The port is partitioned, 
probably due to a network loop. Examine your 
connections and remove the loop. Each piece of 
equipment needs only one connection to your Hub.
Link between the Hub and another 
OfficeConnect hub not working.
 Check your 
connections; follow the information given in the 
“Connecting Another OfficeConnect Hub” section on 
page 5. It is likely that an MDI/MDIX switch is 
incorrectly set.
Alert LED continuously lit. There is a problem with 
the network. Check the Port Status LEDs to try to 
identify the port that is causing the problem. If one 
of the Port Status LEDs is flashing, that port has 
partitioned, probably due to a network loop. Examine 
your connections and remove the loop. Each piece of 
equipment needs only one connection to your Hub.
If you cannot identify such a port, remove the port 
connections one at a time, waiting a few seconds 
between each port. If the Alert LED goes off, there is 
either a network loop (see above), or an excessive 
amount of traffic on that port connection. Check the 
Network Utilization LEDs to see if the network is 
heavily loaded (over 80%). Some pieces of network 
equipment operate by sending out frames regularly. 
Refer to the documentation that accompanies the 
piece of network equipment.
If the Alert LED is still lit after removing all of your 
connections, there may be a problem with your Hub. 
Power it off, wait about 5 seconds and then power it 
on. If the Alert LED comes back on continuously, 
contact your supplier.
Dimensions and Operating Conditions
OfficeConnect Dual Speed Hub 16
Standards
Functional:
ISO 8802/3
IEEE 802.3, 802.3u
Safety:
UL 1950, EN 60950
CSA 22.2 #950, IEC 950
Emissions:
EN 55022 Class B*
FCC Part 15 Class B*
ICES-003 Class B*
VCCI Class B*
AS/NZS 3548 Class B*
EN50082-1
CNS 13438 Class A
* Screened (shielded) cables must be used to ensure 
compliance with these EMC standards. Refer to “EMC 
Statements” on page 8 f
or conditions of operation.
Environmental:
EN 60068 (IEC 68)
Acoustic Noise:
ISO 7779
ISO 9295