Справочник Пользователя для 3com 4007

Скачать
Страница из 92
54
C
HAPTER
 6: M
AINTAINING
 
THE
 S
WITCH
 4007
Removing and Replacing a Power Supply 
This section describes how to remove and then 
replace the 930-watt AC power supply 
(Model Number 3CB9EP9) in the Switch 4007 chassis. 
CAUTION: When you replace a power supply, leave a 
sufficient number of power supplies running at all 
times to satisfy the power requirements of installed 
modules. If you have an installed Enterprise 
Management Engine (EME), enter the 
show power 
budget
 command to display current power conditions 
for the Switch 4007. If you determine that removal of 
a defective, but still functioning, power supply will 
not cause a power deficit in the Switch, you can 
remove the faulty power supply without losing power 
to any modules. 
WARNING: Before you attempt to remove a 
930-watt AC power supply from the chassis, to avoid 
contact with hazardous energy, be sure to set the 
power supply’s Standby/On switch (Figure 24) to the 
Standby position, and to disconnect the power cord 
from both the electrical outlet and then the power 
supply. 
There are no user-serviceable parts on either the 
load-sharing power supplies or on the fan trays. If 
these components fail, remove them as described 
here and return the components to your supplier. 
Keep replacement power supply units and fan trays at 
your site so that they are available if needed.
Removing a 930-watt Power Supply 
The Switch 4007 chassis can accommodate up to two 
930-watt modular load-sharing power supplies. 
To remove a 930-watt power supply from a 
Switch 4007 chassis: 
1
Set the power supply’s Standby/On switch (Figure 22), 
which is located on the front of the power supply, to 
the Standby position. 
Figure 22   930-watt Power Supply Standby/On Switch
2
Remove the power cord from the electrical outlet. 
3
Remove the power cord from the power supply’s AC 
input socket. 
Standby/On
switch
On position
Standby position