Справочник Пользователя для Panasonic 1200N

Скачать
Страница из 256
Setting up LAN Emulation
Basic Configuration and Setup
8-12
Centillion 1200N ATM Switch User Manual
NTP 297-8103-903
Adjust ILMI timing parameters. This is specific to a connection to an ATM-
NIC. Use the following values:  Timer value = 5, Times of retry = 60 (default) 
and Keepalive = 20.
8.
Before svcline can be turned on, you must:
SET  signaling  00  0  5
SET  signaling  03  0  5
9.
When connecting two switches together, one has to be set to Network side and 
another set to User side. (In this example, 8550-LES is set to Network side; 
therefore, 8550 must be set to User side.)
For PNNI interface port 00:
SET atmsig  00  0
Interface  (network|0  user|1)?  1
T303  (1-255,default=4)?  4
T308  (1-511,default=30)?  30
T309  (1-511,default=90)?  90
T310  (1-255,default=10)?  10
T313  (1-255,default=4)?  4
T316  (1-511,default=120)?  120
T317  (1-255,default=60)?  60
T322  (1-255,default=4)?  4
T398  (1-255,default=4)?  4
T399  (1-511,default=14)?  4
UNI Version (UNI3.0|0 UNI3.1|1,default=3.0)? 3.0
10.
For UNI interface port 03:
SET atmsig  03  0
Interface  (network|0  user|1)?  0
T303  (1-255,default=4)?  4
T308  (1-511,default=30)?  30
T309  (1-511,default=90)?  90
T310  (1-255,default=10)?  10
T313  (1-255,default=4)?  4
T316  (1-511,default=120)?  120
T317  (1-255,default=60)?  60
T322  (1-255,default=4)?  4
T398  (1-255,default=4)?  4
T399  (1-511,default=14)?  4
UNI Version (UNI3.0|0 UNI3.1|1,default=3.0)? 3.0
SET  svcline  00  resume
SET  svcline  03  resume
Re-set the signaling connection deleted
previously.  A signaling connection is set
with VPI/VCI=0/5
Set UNI 3.0