Справочник Пользователя для Siemens 6ED1050-1AA00-0BE8
Programming LOGO!
3.7 Writing and starting the circuit program
LOGO!
Manual, 04/2011, A5E03556174-01
Manual, 04/2011, A5E03556174-01
105
3.7.8
Deleting a block
Let us assume you want to delete the block B2 from your circuit program and connect B1
directly to Q1.
,
,
,
[
[
4
ุ
3DU
%
%
Proceed as follows:
1. Switch LOGO! to programming mode
1. Switch LOGO! to programming mode
(as a reminder, refer to the topic "The four golden rules for operating LOGO!" (Page 79)).
0VJ&RQILJ
3DVVZRUG
&OHDU3UJ
!(GLW
2. Select "
①
": Press or
3. Confirm"
①
": Press OK
(If required, enter your password and confirm with OK.)
4. Select "
②
": Press or
$4
0HPRU\"
(GLW1DPH
!(GLW3UJ
5. Confirm "
②
": Press OK
6. Move the cursor to B2, the input of Q1: Press
%4
7. Confirm with OK.
8. Now replace block B2 with block B1 at output Q1. The procedure:
8. Now replace block B2 with block B1 at output Q1. The procedure:
– Select the BN list: Press or
– Accept the BN list: Press OK
– Select 'B1': Press or
– Apply 'B1': Press OK
– Accept the BN list: Press OK
– Select 'B1': Press or
– Apply 'B1': Press OK
Result: Block B2 is deleted, because it is no longer used in the circuit. Block B1 has replaced
B2 directly at the output.