Справочник Пользователя для Fortinet 5003

Скачать
Страница из 128
FortiSwitch-5003A and 5003   Fabric and Base Backplane Communications Guide
12
01-30000-85717-20081205
Front panel LEDs and connectors
FortiSwitch-5003A system
Base channel interfaces
 lists and describes the FortiSwitch-5003A base backplane channel 
interfaces. The base backplane interfaces are not configurable or visible from the 
FortiSwitch-5003A CLI.
Figure 2: FortiSwitch-5003A base network activity LEDs
BASE 10G, 14/F8, F7, 
F6, F5, F4, F3, F2, F1 
(Base and Fabric 10 
gigabit LEDs)
Solid 
Green
Indicates this interface is connected to a 10-gigabit 
network device with the correct cable and the 
attached network device has power.
Blinking 
Green
Indicates 10-gigabit network traffic on this interface.
Off
No link.
HS (Hot Swap)
Blue
The FortiSwitch-5003A is ready to be hot-swapped 
(removed from the chassis). If the HS light is blue 
and no other LEDs are lit the FortiSwitch-5003A 
board has lost power
Flashing 
Blue
The FortiSwitch-5003A is changing from hot swap to 
running mode or from running mode to hot swap. 
This happens when the FortiSwitch-5003A board is 
starting up or shutting down.
Off
Normal operation. The FortiSwitch-5003A board is in 
contact with the chassis backplane.
Table 2: FortiSwitch-5003A front panel LEDs and switches  (Continued)
LED
State
Description
Table 3: Base channel interfaces and network activity LEDs
Interface 
Name
Description
SH1
If the FortiSwitch-5003A board is in the first hub/switch fabric slot, this 
LED indicates a backplane connection to shelf manager 1. If the 
FortiSwitch-5003A board is in second hub/switch fabric slot this LED 
indicates a backplane connection to shelf manager 2.
This LED may not be lit even if a shelf manager is present if the shelf 
manager is configured to use its front panel interface.
15 and SH2
Not used. 
2/1
Base channel connection between base channels 1 and 2. 
The 2/1 LED is lit if there is any board capable of connecting to the base 
channel in the other slot. For example, if the FortiSwitch-5003A board is 
installed in the first hub/switch fabric slot, this LED will be lit if any board 
is installed in the second hub/switch fabric slot, including a 
FortiSwitch-5003A board or any FortiGate-5000 board.
3 to 14
Base channel connection to FortiGate-5000 boards in chassis slots 3 to 
14.