Справочник Пользователя для Fujitsu MB88121 SERIES

Скачать
Страница из 73
SK-91F467-FLEXRAY V1.1 
Jumpers and Switches 
FMEMCU-UG-910017-11 
- 30 - 
© Fujitsu Microelectronics Europe GmbH 
ON 
OFF 
Dip-Switch S6 
(default setting) 
1
2
3
4
EN WAKE nSTB nc
3.6.3  FT1080 Control Settings (S6)  
The DIP switch S6 is used to set EN, WAKE and nSTB signals of the FlexRay physical layer 
driver modules from TZM (FT1080). The control signals can also be connected with jumper 
to the MCU to give the possibility to set them via user software. Both modules (FT1080) will 
be set simultaneously, if JP48-JP50 and JP73-JP75 are closed. 
DIP switch 
Setting 
Logical value 
ON (closed) 
0 (low) 
S6/1 (EN) 
OFF (open) 
1 (high) 
ON (closed) 
0 (low) 
S6/2 (WAKE) 
OFF (open) 
1 (high) 
ON (closed) 
0 (low) 
S6/3 (nSTB) 
OFF (open) 
1 (high) 
ON (closed) 
Not connected 
S6/4 (Not used) 
OFF (open) 
Not connected 
Default: grey 
Table 3-13: FT1080 Control Settings 
 
Figure 3-5: FT1080 Control Switch 
JP31  Connects nSTB signal of FT1080 modules to MCU port 18_6 
JP32  Connects WAKE signal of FT1080 modules to MCU port 18_5 
JP33  Connects EN signal of FT1080 modules to MCU port 18_4 
Jumper 
Setting 
Description 
ON (closed) 
nSTB is connected to MCU P18_6 
JP31 
OFF (open) 
No connection to the microcontroller 
ON (closed) 
WAKE is connected to MCU P18_5 
JP32 
OFF (open) 
No connection to the microcontroller 
ON (closed) 
EN is connected to MCU P18_4 
JP33 
OFF (open) 
No connection to the microcontroller 
Default: grey 
Table 3-14: FT1080 Connection to MCU