Справочник Пользователя для Pioneer k DVD-RW 16x4 int ATAPI 10pk bulk black DVR-108BK?10PK

Модели
DVR-108BK?10PK
Скачать
Страница из 48
R8 Series Drive Command Reference Manual  
Version 0.90
 
Page  14 
 
4.3 FORMAT UNIT Command 
The CmpLst bit is not supported and must be set to zero. 
The Interleave Value field is not supported and must be set to zero. 
The Format Code field allows the value of 001b and 111b. If Format Code field is set to 001b and a CD-RW or a DVD -RW media is 
mounted, the drive conforms for the definition of SFFC INF-8090i. If Format Code is set to 001b and a +RW media is mounted, the 
drive conform for the definition of MMC-4. If Format Code is set to 111b and CD-RW media is mounted, the drive conforms for 
legacy specifications which is described in the definition of MMC-4. 
The drive supports following Format Type for each media. 
Table 4 - Format Code = 001b 
Format 
Type 
Name 
Support for 
CD-RW 
media 
Support for 
DVD -RW 
media 
Support for 
+RW media 
00h 
Full Format 
yes  
yes  
no 
10h 
C/DVD-RW Full Format 
yes 
yes  
11h 
C/DVD-RW Grow Session/Border 
no 
no 
12h 
C/DVD-RW Add Session/Border 
no 
no 
13h 
DVD-RW Quick Grow the last Border 
yes  
14h 
DVD-RW Quick Add Border 
no 
15h 
DVD-RW Quick 
yes  
Table 5 - Format Code = 111b (CD-RW only) 
Sess bit 
Grow bit 
Support for CD-RW media 
Yes 
No 
No 
No 
The Format Unit parameter list shall be transferred from the Host to the drive. The data sent to the drive consists of a Format List 
Header, followed by one Format descriptor, so the parameter list length is always 12 bytes. When the Format Options Valid (FOV) 
bit in the Format List Header is set to one, the DPRY, DCRT, STPF, IP, Try -out, and VS shall be set to zero. In this case, the format 
operation is performed with an Immed function specified by the Immed bit. When the FOV bit is set to zero, the DPRY, DCRT, 
STPF, IP, Try -out, Immed, and VS shall be set to zero. In this case, the format operation is performed with the drive’s internal default 
setting. The default setting of Immed function is one. Even if the format operation is requested with the FOV bit set to one, the 
drive’s default setting itself will not be changed. 
4.3.1   Format Code = 001b 
4.3.1.1  Format Type = 00h (Full Format) 
Formatting for the entire media is specified. The Number of Blocks field specifies the number of addressable blocks for the entire disc 
and the Type Dependent Parameter field specifies the Block Length. 
If the Immed function is set to zero, the drive will return the status after the format operation has completed. If the Immed bit is set to 
one, the drive will return the status as soon as the command descriptor block has been validated, and the entire Format Descriptor has 
been transferred. 
The READ DISC INFORMATION Command, the READ TRACK/RZONE INFORMATION Command and the TEST UNIT 
READY Command is used to detect completion of the format operation. While format operation is performed by the FORMAT 
UNIT Command that the Immed function is set to one, the drive terminates these commands with the Check Condition status, 
LOGICAL UNIT NOT READY, FORMAT IN PROGRESS (2/04/04). If the drive returns Good status for these command, format 
operation has completed. 
In response to the REQUEST SENSE command, including after the Check Condition status described above, the  drive will return a 
SK/ASC/ASCQ values set to NOT READY/LOGICAL UNIT NOT READY/FORMAT IN PROGRESS, with the sense key specific 
bytes set for progress indication. The SKSV will be set to one and the Progress Indication field will contain 16 bit unsigned value such 
that (Progress  Indication)/65 536 X 100% approximates the percentage of completion of the operation. Once the  operation is 
completed, the SKSV will be cleared to zero.