Справочник Пользователя для Barco 26-0507000-00

Скачать
Страница из 46
BlendPRO-II  •  User’s Guide
27
3.  Installation
Signal Installation
c.  (If your system includes three ScreenPRO-IIs) — Connect the second 
ScreenPRO-II’s GENLOCK LOOP connector to the GENLOCK IN 
connector on the ScreenPRO-II with the next highest numbered ID.
d.  (If your system includes four ScreenPRO-IIs) — Connect the third 
ScreenPRO-II’s GENLOCK LOOP connector to the GENLOCK IN 
connector on the ScreenPRO-II unit with the highest numbered ID.
e.  Set the Termination Switch for all ScreenPRO-IIs in your system:
For all ScreenPRO-IIs except the last one in the chain, ensure 
that the ScreenPRO-II is un-terminated (HI-Z).  Refer to the 
details.
On the last unit in the chain (only), ensure that the 
ScreenPRO-II is terminated (75-OHM).
Please continue with system setup, menu orientation and operations, as outlined in 
Chapter 4, “
pÅêÉÉåmolJff=dÉåäçÅâ=qÉêãáå~íáçå
On the rear of each ScreenPRO-II chassis, one recessed Termination Switch is provided 
for genlock termination (adjacent to the Genlock Loop connector).  
Terminated — when the switch is pushed in, the connection is terminated (75 
Ohms).
Un-terminated — when the switch is out, the connection is un-terminated.
If a particular ScreenPRO-II chassis is the last device in a reference video chain, ensure 
that the Termination Switch is pushed in.  If a particular ScreenPRO-II chassis is in the 
middle of a reference chain, ensure that the Termination Switch is out.