Справочник Пользователя для Barco DCS-200

Скачать
Страница из 170
DCS-200  •  User’s Guide
59
4.  Operation
Using the Setup Menu
When sampling is set to OverSample, values represent the oversampling factor 
being used.
For all Horizontal “active area” fields, all units are measured in pixels: 
H Total — adjusts the total pixel count per line.  This value cannot be adjusted if 
the input type is DVI / SDI.
H Position — adjusts the offset of start of active area from H sync. 
H Active — sets the size of the active area. 
For all Vertical “active area” fields, all unit are measured in lines. 
V Total — indicates the total line count per frame.  This value is measured, and 
can never be adjusted.  Its value will always be shown in brackets.
V Position — sets the offset of start of active area from V sync. 
V Active — sets the size of the active area. 
^ÇàìëíáåÖ=p~ãéäÉ=mÜ~ëÉ
The DCS-200 has two A-to-D converters, which are referred to as A and B in the Timing 
Adjust Menu
.  The sample phase value of each scaler is initially filled in by the Auto 
Config
 command, or set to the default value of 0 (zero).  If required, advanced users can 
fine-tune the image by adjusting the sample clock phase of each scaler directly — but only 
for inputs whose “type” is analog
.
Adjustment range
:  -16 to 15
Default
:  0
„
Use the following steps to adjust sample clock phase of each scaler, for inputs whose 
“type” is analog.
1.  From the Input Menu, navigate to the Timing Adjust Menu, and scroll to the 
Phase A or Phase B line.
2.  In the Inputs Section, select an input whose “type” is analog.
3. TAKE 
the input to Program.  The button lights solid.
4.  Pend the same input for the next transition.  In this mode, only one button will now 
be lit solid, and no buttons will be blinking.
5.  On the Timing Adjust Menu, note that one of the two Phase lines will be 
bracketed, and the other will be unbracketed.  When you press TAKE, the 
brackets will switch positions.  The un-bracketed line is the active scaler. 
Figure 4-25.  Timing Adjust Menu, phase indication of active scaler
6.  On the selected input, put up a Burst pattern.  For example, if the source is a 
computer, use a program such as DisplayMate
®
 to generate the pattern.
7.  Scroll to the unbracketed Phase line, and press SEL.
8.  Use the Adjust knob to tweak the burst pattern for the maximum visual clarity and 
a minimum amount of visual noise, then press SEL to accept the new value.
T I M I N G   A D J U S T
S a m p l i n g
1 : 1
> P h a s e   A
0
P h a s e   B
[ 0 ]