Справочник Пользователя для Minicom Advanced Systems Smart CAT5

Скачать
Страница из 45
SMART CAT5 SWITCH – 108/116 
 
 
35
 
 
Figure 29 Com Option box 
3.  Choose the Com Port the RS232 Serial cable is connected to and click OK. 
6.4.1 Verifying the version numbers 
Before upgrading the firmware, you must first verify which firmware and hardware 
versions you have.  
6.4.1.1 OSD version number 
To verify the OSD version number: 
1.  In the Switch Unit box, check the OSD option. See  Figure 28. 
2.  Click 
. The version number appears in the Switch box.  
The H/W Version button is grayed out, as there is no hardware relevant to the OSD. 
6.4.1.2 Smart CAT5 Manager version number 
To verify the Smart CAT5 version number: 
1.  In the Switch Unit box, check the Smart CAT5 Manager option. 
2.  Click 
. The firmware version number appears in the Switch 
Unit box. 
3.  Click 
. The hardware version number appears in the Switch 
Unit box. 
6.4.1.3 RoC/RICC version number 
To verify the RICC version number: 
1.  Before you can check a RoC/RICC, you must uncheck the Switch Unit box 
options. 
2.  Check one or more or all of the RoC/RICCs. 
3.  Click 
. The firmware version number appears after the 
RoC/RICC number.