 Appendix B: Rack mount configuration
122
Elevated operating ambient temperature 
The maximum operating temperature of the system is 35°C (95°F).  
Careful consideration should be given to installing the system in 
an environment compatible with the 35°C (95°F) maximum 
ambient temperature.
Reduced airflow 
The amount of airflow required for the safe operation of the 
equipment should not be compromised when installing the system 
in a rack.
Mechanical loading 
Exercise care when mounting the system in a rack to avoid any 
accidents.
Circuit overloading 
Appropriate consideration should be given when connecting the 
supply circuit to the system to avoid any circuit overload.  The 
system name plate rating should be used when addressing 
concerns about circuit overload.
Rack mount kit
The rack mount kit components and their respective function is listed 
on the table below. 
Component
Quantity
Usage
Mounting rails
2
Allows the server to slide in and out of the 
rackmount for maintenance purposes.
Each mounting rail consists of the 
following: 
• Fixed outer rail.  Attaches to system rack 
with M6 x 13 screws. 
• Inner rail.  Attaches to the sides of the 
server with M4 x 5 screws. 
• Middle sliding piece has a steel ball 
gearing to control server movement 
from and into the rackmount.