 Appendix A: System rack installation
148
Rack conversion procedures
This section describes the procedures to install the contents of the rack 
conversion kit.  Unless otherwise specified, all references to chassis 
directions (top, bottom, left, right, front, and rear) refer to a chassis in 
rack orientation when you are facing the front of the chassis.
Installation overview
Installing the contents of the rack conversion kit involves the following 
steps:
Removing the bottom panel
Removing the left panel
Removing the original tower bezel
Removing the feet
Installing the rack bezel
Installing the bushings on the chassis
Installing the handles and rails (see the note below)
Note:  You also need the manual from the rack-mount rail kit to 
complete this installation. 
The following sections describe the above procedures in detail.
Removing the bottom panel
1
Orient the server so it is resting on its feet as shown in Figure 58.
2
Remove the two screws (Figure 58, A) located on the rear edge of 
the bottom panel.
3
Slide the panel toward the rear of the chassis (Figure 58, B).
4
Using the orientation shown in Figure 60 as a reference, grasp the 
bottom edge of the cover (Figure 58, C) and tilt it out.  Then lift 
the cover straight up (Figure 58, D) to free it from the tabs on the 
chassis.