Fitting rules for connection blades
The connection blade slots of the BX400 S1 system unit are numbered as
follows.
follows.
Figure 34: Connection blade slots
The connection blade slots are connected to a so-called fabric. The following
table shows how you can fill the fabrics and which network components of the
server blades they are connected to:
table shows how you can fill the fabrics and which network components of the
server blades they are connected to:
I
Connection blades within one fabric must have the same technology, i.e.
either Ethernet or Fibre Channel or Infiniband.
either Ethernet or Fibre Channel or Infiniband.
When filling the slots in fabrics 2 and 3, also make sure the server blades are
fitted with the appropriate mezzanine cards. The following rules apply for fitting
the mezzanine card slots of the server blades:
fitted with the appropriate mezzanine cards. The following rules apply for fitting
the mezzanine card slots of the server blades:
●
If a 1 Gb Ethernet mezzanine card is installed in slot 1 of a server blade, at
least one 1 Gb Ethernet connection blade must be installed in CB slot 2 of
the system unit.
least one 1 Gb Ethernet connection blade must be installed in CB slot 2 of
the system unit.
Server blade
Midplane
Connection blade slots
Onboard LAN
Fabric 1
CB1:
1 or 10 Gb Ethernet
Mezzanine
card slot 1
Fabric 2
CB2:
1 or 10 Gb Ethernet or Fibre Channel
Mezzanine
card slot 2
Fabric 3
CB3:
1 or 10 Gb Ethernet or Fibre Channel
or Infinband
CB4:
1 or 10 Gb Ethernet or Fibre Channel
Table 4: Fitting rules for connection blade slots