Справочник Пользователя для Fujitsu BX400 S1
![Fujitsu](https://files.manualsbrain.com/attachments/6c4642b33d2edbd09f94719c20a133aa0e862902/common/fit/150/50/80a45702a21fefb1823bce6851e87db450dccf7792cb572ebc8a90330a68/brand_logo.png)
BX400 S1
Operating Manual
103
Hot-plug components
2
Health indicator (green/yellow) (controlled by management blade)
Dark:
Boot phase; connection blade was still not recognized by MMB
Lights up green:
Connection blade is running
Lights up yellow:
Hardware/functional error or overheating
3
Hidden reset button
4
Status indicator (green/orange)
Dark:
Connection blade is not running or is defective
Lights up green:
Connection blade is running
Lights up orange:
Boot phase; one or more ports are offline; restarting connection
Flashes
orange/green:
orange/green:
Warning: An error has occurred.
The LED can also flash during a test.
A
External FC ports (8x)
Ports for FC SFP Multi-Mode (MMF) or FC SFP+ Multi-Mode (MMF) SFP modules
B
Status indicators for external FC ports (green/orange)
Dark:
No signal reception
Flickers green:
FC port online, data transport
Flashes green:
–
Slow: FC port online, but segmented
–
Fast: Internal loop
Lights up orange:
Signal reception, but not online
Flashes orange:
Slow (~ 2 sec. interval): FC port deactivated.
Fast (~ 0.5 sec. interval): FC port defective
C
Management LAN port